Worcester 18/25 Instruction Manual Page 45

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 44
RIELLO
CONTROL BOX OPERATION
This operation instruction is provided to assist competent and suitably qualified engineers to
locate and rectify faults. Whilst every effort has been taken to ensure the information given is
correct and complete we cannot guarantee that every eventuality has been covered.
Worcester, Bosch Group cannot be held responsible for costs incurred by persons not deemed
to be competent.
In the lock-out condition, the oil pump can be primed
for 30 seconds:
1. Press the remote reset button for more than 6 seconds
and then release. The control box lock-out reset will
blink quickly green, orange and red.
2. Re-press the burner reset button and release within
3 seconds and pump priming starts.
Operational Codes
OFF OFF
Initial check time (11 seconds) before pre-purge OFF
Pre-purge (15 seconds) ORANGE Flashing
Safety time (maximum 5 seconds) GREEN Flashing
Running GREEN
Lock-out/Error Codes
False light before ignition GREEN, RED
Under voltage or over voltage RED, ORANGE
lock-out for no flame during safety time RED
Lock-out for false flame signal / RED Flashing
Lock-out for burner control error
Lock-out for maximum number of restarts RED Fast flashing
Pump Priming Cycle
Pump priming cycle GREEN, ORANGE, RED
STATUS CODE ADDITIONAL INFORMATION
Only when the solenoid valve is energised with no flame
signal.
Lock-out and Reset
The control box can be reset consecutively a maximum number of 5 times after which the
power supply has to be reset; then the control box can be reset a further 5 times.
Limit of Restarts
If the flame is lost during operation; the burner will restart 3 times. On the 4th restart the
burner will go to lock-out. By resetting the power supply the control box is reset and allows
3 restarts.
Flame Detection
Flame detection minimum current: 30µA
Flame loss maximum current: 25µA
False flame maximum current (without false light): 19µA
FAULT FINDING
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR DANESMOOR UTILITY 18/25
8 716 106 256C (03/2010)
45
FAULT FINDING
& DIAGRAMS
8 716 106 256 C 03.10 30/3/10 14:24 Page 45
Page view 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 51 52