Worcester ZWB 7-25 HE combi Specifications Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
7 181 465 346 GB (03.02)
17
Failure identification procedure
A7 flashing.
Hot water NTC sensor defective
Check Action
B Note the setting of the temperature controls
and .
1.
B Press button .
B Select service function .2 .
Is a temperature between 0. and
5. displayed?
yes:
B Flue gas connector corroded
1)
, damaged or
dirty? Change relative parts.
2.
no: 3.
2. Hot water NTC sensor:
B Unplug connector.
B Short circuit the connector.
Display changes to
temperature 99.
yes: B Power OFF the appliance.
B Drain the hot water circuit.
B Disconnect the boiler electrical connection.
B Change NTC sensor.
B Plug the connection wire.
B Reconnect the boiler electrical connection.
B Turn ON the appliance.
A7? 3.
no: B Change the 20-pin connector lead assembly.
3.
3. Temperature between 95. and 99. is
displayed.
B Unplug connector.
After max. 60 sec.:
Does the displayed code change
to a value between 0. and 5.?
yes: B Power OFF the appliance.
B Disconnect the boiler electrical connection.
B Change NTC sensor.
B Refill the hot water circuit.
B Check the built-in NTC sensor for leaks.
B Plug the connection wire.
B Reconnect the boiler electrical connection.
B Turn ON the appliance.
A7? 4.
no: 4.
Page view 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 55 56

Comments to this Manuals