GREENSTAR DANESMOOR WALL MOUNTED OIL 12/18 & 18/25WALL MOUNTED OIL FIRED CONDENSING BOILERFOR FULLY PUMPED OPEN VENT OR SEALED CENTRAL HEATING SYS
TIPS ON ENERGY SAVINGGREENSTAR DANESMOOR WALL MOUNTED OIL 12/18 & 18/25 8 718 681 135a (08.08)8ENERGYSAVINGTIPS ON ENERGY SAVINGHeating economica
GREENSTAR DANESMOOR WALL MOUNTED OIL 12/18 & 18/25 8 718 681 135a (08.08)9TIPS ON ENERGY SAVINGENERGYSAVINGTIPS ON ENERGY SAVINGRadiators:More of
MAINTAINING YOUR APPLIANCEGREENSTAR DANESMOOR WALL MOUNTED OIL 12/18 & 18/25 8 718 681 135a (08.08)10MAINTENANCEMAINTAINING YOUR APPLIANCEYour ne
FAULT FINDINGProblem Cause RemedySwitch off boiler atmaster switch, wait afew seconds thenswitch on againCheck settingDesired roomtemperature is notre
FAULT OR BREAKDOWNGREENSTAR DANESMOOR WALL MOUNTED OIL 12/18 & 18/25 8 718 681 135a (08.08)12MAINTENANCEFAULT OR BREAKDOWNThis appliance is suppo
YOUR GUARANTEEThis appliance is guaranteed against faulty materials or workmanship for a period of24 calendar months (60 months for the primary heat e
ModelSerial No.(See identity label inside appliance casing)Type / sizeDate of installationGUARANTEE REGISTRATIONYou should complete and return thepost
NOTESNOTES GREENSTAR DANESMOOR WALL MOUNTED OIL 12/18 & 18/25 8 718 681 135a (08.08)15NOTES
NOTESGREENSTAR DANESMOOR WALL MOUNTED OIL 12/18 & 18/25 8 718 681 135a (08.08)16NOTESNOTES
USER INSTRUCTIONS & CUSTOMER CARE GUIDEPLEASE READ THESE INSTRUCTIONSCAREFULLY BEFORE OPERATING YOURAPPLIANCE.THESE INSTRUCTIONS AREAPPLICABLE TO
USER INSTRUCTIONS &CUSTOMER CARE GUIDEEXCELLENCE COMES AS STANDARDWorcester, Bosch GroupCotswold Way, Warndon, Worcester WR4 9SW.Tel. 01905 754624
CONTENTSGREENSTAR DANESMOOR WALL MOUNTED OIL 12/18 & 18/25 8 718 681 135a (08.08)INTRODUCTIONUSING YOURAPPLIANCEMAINTENANCEENERGYSAVINGGUARANTEEC
SAFETY PRECAUTIONSGREENSTAR DANESMOOR WALL MOUNTED OIL 12/18 & 18/25 8 718 681 135a (08.08)2SAFETY PRECAUTIONSAny misuse or unauthorised modifica
EXCELLENCE COMES AS STANDARDGREENSTAR DANESMOOR WALL MOUNTED OIL 12/18 & 18/25 8 718 681 135a (08.08)3INTRODUCTIONEXCELLENCE COMES AS STANDARDTha
GENERAL INFORMATIONRegularly check the pressure is maintainedand contact your installer or maintenanceengineer if there is a noticeable, permanentdrop
CONTROLSTO GAIN ACCESS TO THE BOILERCONTROLS, PUSH AT THE TOP OFTHE FLAP AND RELEASE1PUSHCONTROLSGREENSTAR DANESMOOR WALL MOUNTED OIL 12/18 & 18
OPERATING THE BOILERSWITCHING THE BOILER ON/OFFSwitching onSwitch on the boiler by pressing thepower button.The indicator light shows blueSwitching o
FAULT CONDITIONS:NORMAL OPERATION:POWER INDICATOR (3) ON, (if thereis a central heating or hot waterdemand there will be a light illuminatedon the pro