7
TRANSMITTER
CLEARANCES & FIXING
FITTING & OPERATING INSTRUCTIONS FOR WORCESTER BOSCH
MT10RF/MECHANICAL RF THERMOSTAT
8-716-106-196 issue c (08.04) UK
6mm
E
D
F
INSTALLATION &
COMMISSIONING
TRANSMITTER CLEARANCES:
See diagram opposite for minimum area
(shown in mm) required for operation.
TRANSMITTER
CLEARANCES & FIXING
TRANSMITTER FIXING:
1 Hold baseplate (B) level to mark
securing points (C) and remove
baseplate (B)
2 Drill holes, where marked, 30mm
deep using a 6mm diameter drill bit
3 Push one wall plug (D) into each hole
4 Reposition baseplate (B), check level
and secure with screws (E)
5 Align outer edge and internal lugs (F)
of transmitter to baseplate (B) and
push fit to secure
CAUTION: Ensure there are no
pipes, electric cables or other
hazards before drilling.
45
250
45 160
75
30mm
B
SAFETY: All relevant safety
precautions must be undertaken.
Protective clothing, footwear,
gloves and safety goggles must be
worn as appropriate.
C
B
1
2
3
4
5
Page view 8